Kidde P3010K-CO Carbon Monoxide & Smoke Detector, 10-Year Worry-Free DC Sealed Lithium Battery Powered for Kitchen
Why Not Kill two birds with one stone? Kidde model P3010K-CO combination carbon Monoxide & smoke detector, comes with a 10-Year Worry-Free DC Sealed Lithium Battery that is powered for your kitchen. The lithium battery does not have to be replaced for the life of the alarm. This Kidde model P3010K-CO combination smoke & carbon detector has the photoelectric sensor which is designed to detect visible particles. The great thing about this alarm is once the alarm is attached to the mounting bracket it automatically self activates. This combination smoke and carbon detector comes with a 10 year warranty and has all the features and specifications to make it a great choice.
Features:
-
Combination Smoke and Carbon Monoxide Alarm - Smoke and CO sensing technologies work together to detect real fires faster and reduce cooking-related nuisance alarms.
-
Sealed-In Lithium Battery - Sealed-in lithium power supply; no battery replacement required over the 10 year life of the alarm. Eliminates worry about battery removal or unauthorized deactivation of alarm.
-
Photoelectric Sensor - Smoke alarm contains advanced photoelectric sensor that may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
-
Self Activation - Alarm automatically activates when attached to the mounting bracket.
-
Alarm Memory - Rapidly flashing LED alerts user if the alarm has sounded since the last time the test/reset button was used.
-
Test/Hush Button - Tests alarm circuitry and activates Hush features.
-
Smart Hush™ - Temporarily silences nuisance alarms for approximately 10 minutes and will not allow hush mode unless the unit is in alarm mode.
-
LED - Red LED will blink in conjunction with the alarm sound.
-
End of Life Warning - Alarm chirps every 30 seconds to indicate the unit is in need of replacement.
-
End of Life Hush® - End of life indication can be silenced three days at a time up to 30 days to allow for alarm replacement at a more convenient time.
-
UL217 and UL2034 Listed
-
10 Year Limited Warranty
Specifications:
Model: | P3010K-CO |
Power Source: | Sealed Lithium Battery |
Sensor: | Smoke: Photoelectric CO: Electrochemical |
Audio Alarm: | 85dB at 10ft |
Temperature Range: | 40˚F (4.4˚C) to 100˚F (37.8˚C) |
Humidity Range: | 10%-85% non-condensing relative humidity (RH) |
Size: | 5.22” in diameter x 1.6” depth |
Weight: | 1 lb. |
Interconnects: | No |
Warranty: | 10 year limited |
Architectural and Engineering Specifications
The combination smoke and carbon monoxide alarm shall be Kidde model number P3010K-CO or approved equal. It shall be powered by a non-replaceable lithium battery with a 10-year life. The lithium battery shall be sealed in the unit to prevent removal and/or tampering. The unit shall incorporate a photoelectric smoke sensor and an electrochemical carbon monoxide sensor. The CO sensor shall be of a fuel cell design and provide accuracy of +/- 20% + 15 PPM. The temperature operating range shall be between 40ºF and 100ºF (4ºC and 38ºC) and the humidity operating range shall be 10%-85% non-condensing relative humidity. The alarm can be installed on the surface of any wall or ceiling following the UL/Manufacturer’s approved placement guidelines. The alarm shall incorporate an automatic activation feature that will activate the unit as soon as it is attached to the mounting bracket, no other steps are involved. The alarm shall include a test button that will electronically simulate the presence of smoke and CO and cause the unit to go into both modes of alarm. This sequence tests the unit’s electronics to ensure proper operation. The CO sensor will not alarm to levels of CO below 30 PPM and will alarm in the following time range when exposed to the corresponding levels of CO. 70 PPM CO Concentration 60 – 240 Minutes 150 PPM CO Concentration 10 – 50 Minutes 400 PPM CO Concentration 4 – 15 Minutes The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. For a CO incident, the horn will sound in the repetitive manner – four (4) fast beeps, a short pause, four (4) fast beeps, a short pause. In a smoke incident, the horn will sound in the repetitive manner – three (3) beeps, a pause, three (3) beeps, a pause. The red LED will flash in conjunction with the alarm sound. The unit shall indicate a low battery condition with a brief alarm chirp and LED flash once every 30 seconds. In standby condition, the LED will flash every 60 seconds for the first 10 minutes following power on or test, and once every 10 minutes thereafter. It will also flash every 10 seconds while in Hush mode. The smoke alarm shall include an End of Life Alert, where ten years after initial power-up the unit shall chirp two times every 30 seconds to indicate the alarm needs to be replaced. The End of Life indication can be silenced for 3 days at a time for a maximum of 30 days. The unit shall have a deactivation switch to disable it and make it safe for disposal. The unit shall at a minimum meet the requirements of UL217, UL 2034, NFPA 72, (chapter 11 2002 edition) The State of California Fire Marshall, NFPA 101 (One and two family dwellings), Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty.